Instruction Manual
[Version 1.00]
Table of Contents
WARNING:
Introduction
Special Features
Warning and Safety Notes
Program Flow Chart
Explanation of Buttons
Power and Battery Connection
Charge Operation
Lithium Battery Program (LiPo/LiFe/Lilon/LiHV)
NiMH/NiCd Battery Program
Pb Lead-acid Battery Program
DJI Battery Program
DC/DC Converter
Battery Memory Set and Call Out
System Setting
Battery Voltage Meter
Battery Resistance Meter
Warning and Error Message
The Set Contains
Specification
Conformity Declaration
Regulatory Information
Commonly Used Terms
Warranty and Service
01
03
05
08
10
11
13
14
17
22
26
28
29
31
33
34
35
36
37
38
39
40
41
Congratulations on your choice of SKYRC B6 V2 DC Balance
Charger/Discharger. This unit is simple to use, but the operation
of a sophisticated automatic charger such as SKYRC B6 does
require some knowledge on the part of the user. These operating
instructions are designed to ensure that you quickly become
familiar with its functions. It is therefore important that you read
right through the Operating Instructions, Warning and Safety
Notes before you attempt to use your new charger for the first
time. We hope you have many years of pleasure and success
with your new battery charger.
SkyRC B6 V2 is a high-performance, micro processor control
charge/discharge with battery management suitable for use with
all current battery types(LiPo/LiFe/Li-Ion/LiHV/NiMH/NiCd/Pb)
batteries.The charger deliver dedicated 60W integrated power
and can fill battery at up to 6A. Except SkyRC normal charging
programs, it is versatile with the addition of AGM and Cold modes
for Lead Acid(Pb) battery.
This charger can be powered by 11-18V DC, it is able to power
DC equipment such as LED pit light, motor checker, etc.
Please BE SURE to read these INSTRUCTIONS, WARNING and
SAFETY NOTES before you use the charger for the first time.It
can be dangerous to mis-handle batteries and battery chargers,
as there is always a risk of batteries catching fire and exploding.
Mishandling batteries and battery
chargers is extremely dangerous,
which may cause fire and explosion.
Introduction
01 ·B6 V2
Never leave the charger unattended
when charging the battery.
LiPo batteries pose a severe risk of
fire if not properly handled.
Introduction
Please read this entire operating manual completely and
attentively before using this product, as it covers a wide range of
information on operating and safety. Or please do use this
product in company with a specialist!
LCD Display
DC Input
11-18V
Scroll Through
the Main Menu
Stop Any Charge
Processes
Alter Values
See the Status
of Individual Cells
Resume or Start
Charge Processes
Temperature
Sensor Port
Output Socket
Balance Lead Socket
Voltage Calibration (for expert user only)
SkyRC B6 V2 allows you to calibrate the voltage directly on the
device with a 6S LiPo battery. (For more information please contact
Battery Memory (Data Store/Load)
The charger can store up to 10 different charge/discharge profiles for
each channel. You can keep the data pertaining to program setting of
the battery of continuous charging or discharging. Users can call out
these data at any time without any special program setting.
Terminal Voltage Control(TVC)
The charger allows user to change the end voltage. (for expert user only)
Balancing Individual Cells Battery During Discharging
During the process of discharging, SKYRC B6 V2 can monitor and
balance each cell of the battery individually. Error message will be
indicated and the process will be ended automatically if the voltage of
any single one cell is abnormal.
Memory of Last Operation
SkyRC B6 V2 will memorize your last operation of charging/
discharging before power off.
AGM Charge and Cold Charge
For Pb batteries, there are two more charging modes: AGM charge
and Cold charge.
Optimized Operating Software
SkyRC B6 V2 features the so-called AUTO function that sets the
feeding current during the process of charging/discharging. For
Lithium batteries, it can help prevent overcharging which may lead to
explosion. It will disconnect the circuit automatically and alarm once
detecting malfunction, to achieve maximum safety and minimize the
trouble. All the settings can be configured by users.
Special Features
· 02 B6 V2 03 ·B6 V2
DJI Battery Program
SkyRC B6 V2 can charge batteries for DJI Mavic/Inspire with the
maximum charge current of 4A.
DC/DC Converter
SkyRC B6 V2 charger is integrated with DC power input, pumping max
power of 60W with the voltage ranging of 5-26V and 1-6A current.
These warnings and safety notes are particularly important.
Please follow the instructions for maximum safety;
otherwise the charger and the battery can be damaged or at
worst it can cause a fire.
Never leave the charger unattended when it is connected to its
power supply. If any malfunction is found, TERMINATE THE
PROCESS AT ONCE and refer to the operation manual.
Keep the charger well away from dust, damp, rain, heat, direct
sunshine and vibration. Never drop it.
The allowable DC input 11-18V.
This charger and the battery should be put on a heat-resistant,
noninflammable and nonconductive surface. Never place them on
a car seat, carpet or similar. Keep all the inflammable volatile
materials away from operating area.
Make sure you know the specifications of the battery to be
charged or discharged to ensure it meets the requirements of this
charger. If the program is set up incorrectly, the battery and
charger may be damaged .It can cause fire or explosion due to
overcharging.
Be very careful to choose the correct voltage for different types of
battery otherwise you may cause damage to the batteries. Incorrect
settings could cause the cells to fire or explode.
Standard Battery Parameters
3.7V/cell
Nominal
Voltage
Min. Discharge
Voltage
Max Charge
Voltage
Storage
Voltage
Allowable
Fast Charge
3.7V/cell
4.2V/cell
3.8V/cell
1C
LiPo
LiIon
3.6V/cell
4.1V/cell
1C
3.3V/cell
3.6V/cell
3.3V/cell
4C
LiFe
3.0-3.3V/cell 2.9-3.2V/cell
2.6-2.9V/cell
1.2V/cell
1.5V/cell
n/a
1C-2C
NiCd
1.2V/cell
1.5V/cell
n/a
1C-2C
NiMH
2.0V/cell
2.46V/cell
n/a
0.4C
Pb
0.1-1.1V/cell 0.1-1.1V/cell
1.8V/cell
LiHV
3.7V/cell
4.35V/cell
3.85V/cell
1C
3.1-3.4V/cell
Special Features
Re-Peak Mode of NiMH/NiCd Battery
In re-peak charge mode, the charger can peak charge the battery
once, twice or three times in a row automatically. This is good for
making the battery fully charged.
Cyclic Charging/Discharging
1 to 5 cyclic and continuous process of charge > discharge or
discharge > charge is operable for battery refreshing and balancing
to stimulate the battery's activity.
Battery Voltage Meter
The user can check battery's total voltage, the highest voltage, the
lowest voltage and each cell's voltage.
Capacity Limit
The charging capacity is always calculated as the charging current
multiplied by time. If the charging capacity exceeds the limit, the
process will be terminated automatically when you set the maximum
value.
Temperature Threshold*
The battery's internal chemical reaction will cause the temperature of
the battery to rise. If the temperature limit is reached, the process will
be terminated.
* This function is only available by connecting optional temperature
probe, which is not included in the package.
Processing Time Limit
You can also limit the maximum process time to avoid any possible
defect.
Battery Internal Resistance Meter
The user can check battery voltage and battery internal resistance.
Warning and Safety Notes
· 04 B6 V2 05 ·B6 V2
Storage Mode of Lithium Battery
“STORAGE” has the capacity to control the final battery voltage,
which is necessary and helpful for a rarely used battery.
Discharging
The main purpose of discharging is to clean residual capacity of
the battery, or to reduce the battery voltage to a defined level. The
same attention should be paid to the discharging process as
charging. The final discharge voltage should be set up correctly to
avoid deep-discharging. Lithium battery can not be discharged to
lower than the minimum voltage, or it will cause a rapid loss of
capacity or a total failure. Generally, lithium battery doesn't need
to be discharged. Please pay attention to the minimum voltage of
lithium battery to protect the battery.
Some rechargeable batteries have a memory effect. If they are
partly used and recharged before the whole charge is
accomplished, they remember this and will only use that part of
their capacity next time. This is a memory effect . It is said that
NiCd and NiMH batteries are suffering from memory effect. NiCd
has more memory effect than NiMH.
A battery pack which consists of different types of cells (including
different manufacturers)
A battery that is already fully charged or just slightly discharged.
Non-rechargeable batteries (Explosion hazard).
Batteries that require a different charge technique from NiCd,
NiMh, LiPo or Gel cell (Pb, Lead acid).
A faulty or damaged battery.
A battery fitted with an integral charge circuit or a protection circuit.
Batteries installed in a device or which are electrically linked to
other components.
Batteries that are not expressly stated by the manufacturer to be
suitable for the currents the charger delivers during the charge
process.
Please bear in mind the following points before
commencing charging:
Did you select the appropriate program suitable for the type of
battery you are charging?
Did you set up adequate current for charging or discharging?
Have you checked the battery voltage? Lithium battery packs can
be wired in parallel and in series, i.e. a 2 cell pack can be 3.7V (in
parallel) or 7.4V (in series).
Have you checked that all connections are firm and secure?
Make sure there are no intermittent contacts at any point in the
circuit.
Charging
During charge process, a specific quantity of electrical energy is
fed into the battery. The charge quantity is calculated by multiplying
charge current by charge time. The maximum permissible charge
current varies depending on the battery type or its performance,
and can be found in the information by the battery manufacturer.
Only batteries that are expressly stated to be capable of quick-
charge are allowed to be charged at rates higher than the standard
charge current.
Connect the battery to the terminal of the charger: red is positive
and black is negative. Due to the difference between resistance of
cable and connector, the charger can not detect resistance of the
battery pack, the essential requirement for the charger to work
properly is that the charge lead should be of adequate conductor
cross-section, and high quality connectors which are normally gold-
plated should be fitted to both ends.
Always refer to the manual by battery manufacturer about charging
methods, recommended charging current and charging time.
Especially, the lithium battery should be charged according the
charging instruction provided by the manufacturer strictly.
Attention should be paid to the connection of lithium battery
especially.
Do not attempt to disassemble the battery pack arbitrarily.
Please get highlighted that lithium battery packs can be wired in
parallel and in series. In the parallel connection, the battery s
capacity is calculated by multiplying single battery capacity by the
number of cells with total voltage stay the same. The voltage s
imbalance may cause fire or explosion .Lithium battery is
recommended to charge in series.
Never attempt to charge or discharge the following types
of batteries.
Warning and Safety Notes Warning and Safety Notes
· 06 B6 V2 07 ·B6 V2
Program Flow Chart Program Flow Chart
Pb NORMAL CHG
2.0A 4.0V (2P)
BATT/PROGRAM
BATT MEMORY
ENTER
[ BATT MEMORY 1 ]
ENTER SET->
ENTER
BATT TYPE
LiPo
BATT VOLTAGE
7.4V ( 2S )
CHARGE CURRENT
2.0A
DISCHG CURRENT
1.0A
DISCHG VOLTAGE
3.2V/CELL
TVC=YOUR RISK
4.20V
ENTER
ENTER
BATT/PROGRAM
SYSTEM SETTING->
Rest Time
CHG>DCHG 10Min
ENTER
Safety Timer
ON 120Min
Capacity Cut-Off
ON 5000mAH
Temperature Unit
Celsius
Key Beep ON
Buzzer ON
Stop
BATT PROG
SAVE PROGRAM
ENTER
SAVE PROGRAM
SAVE….
[ BATT MEMORY 1 ]
LiPo 7.4V (2S )
[ BATT MEMORY 1 ]
C:2.0A D:1.0A
BATT TYPE
NiMH
BATT VOLTAGE
2.4V (2S)
ENTER
CHARGE CURRENT
2.0A
TRICKLE
100mA
PEAK DELAY
1Min
DISCHG CURRENT
1.0A
DISCHG VOLTAGE
0.5V/CELL
SAVE PROGRAM
ENTER
ENTER
BATT TYPE
Pb
BATT VOLTAGE
4.0V (2P)
CHARGE CURRENT
2.0A
DISCHG CURRENT
1.0A
DISCHG VOLTAGE
1.8V/CELL
SAVE PROGRAM
ENTER
BATT/PROGRAM
Pb BATT
Pb DISCHARGE
1.0A 4.0V (2P)
BATT/PROGRAM
NiCd BATT
NiCd CHARGE
CURRENT 2.0A
ENTER
BATT/PROGRAM
NiMH BATT
ENTER
NiMH CHARGE
CURRENT 2.0A
BATT/PROGRAM
LiPo BATT
LiPo BALANCE CHG
2.0A 7.4V (2S)
LiPo CHARGE
2.0A 7.4V (2S)
ENTER
BATT/PROGRAM
LiFe BATT
Lilo BALANCE CHG
2.0A 7.2V (2S)
Lilo CHARGE
2.0A 7.2V (2S)
ENTER
BATT/PROGRAM
LiIo BATT
LiFe BALANCE CHG
2.0A 6.6V (2S)
LiFe CHARGE
2.0A 6.6V (2S)
ENTER
Temp Cut-Off
ON 50°C 122°F
Version
HW:1.00 SW: 1.04
Load Factory Set
Enter
ENTER
ENTER>3Seconds
NiMH Sensitivity
D.Peak  4mV
NiCd Sensitivity
D.Peak  4mV
DC Input Low
Cut-Off 11.0V
SAVE PROGRAM
SAVE….
ENTER
[ BATT MEMORY 2 ]
NiMH 2.4V (2S )
[ BATT MEMORY 2 ]
C:2.0A D:1.0A
ENTER>3Seconds
[ BATT MEMORY 2 ]
ENTER SET->
[ BATT MEMORY 3 ]
ENTER SET->
SAVE PROGRAM
SAVE….
ENTER
[ BATT MEMORY 3 ]
Pb 4.0V (2S )
[ BATT MEMORY 3 ]
C:2.0A D:1.0A
Pb DISCHARGE
1.0A 4.0V(2P)
BATT/PROGRAM
LiHV BATT
LiHV BALANCE CHG
2.0A 7.6V (2S)
LiHV CHARGE
2.0A 7.6V (2S)
ENTER
LiPo STORAGE
2.0A 7.4V (2S)
LiPo DISCHARGE
1.0A 7.4V (2S)
Lilo STORAGE
2.0A 7.2V (2S)
Lilo DISCHARGE
1.0A 7.2V (2S)
LiFe STORAGE
2.0A 6.6V (2S)
LiFe DISCHARGE
1.0A 6.6V (2S)
LiHV STORAGE
2.0A 7.6V (2S)
LiHV DISCHARGE
1.0A 7.6V (2S)
NiCd DISCHARGE
1.0A CUT: 3.2V
NiCd CYCLE
CHG>DCHG  1
NiMH DISCHARGE
1.0A CUT: 3.2V
NiMH CYCLE
CHG>DCHG 1
NiMH RE-PEAK
1
NiCd RE-PEAK
1
ENTER
Pb NORMAL CHG
2.0A 4.0V (2P)
Pb AGM CHG
2.0A 4.0V (2P)
Pb COLD CHG
2.0A 4.0V (2P)
Pb AGM CHG
2.0A 4.0V (2P)
DEC
INC
Pb COLD CHG
2.0A 4.0V (2P)
ENTER
BATT/PROGRAM
TOOL KITS
BATTERY VOLTAGE
METER
DJI DRONE BATT
TB4X
DJI DRONE BATT
Mavic
BATTERY INTERNAL
RESISTANCE
ENTER
5 3 3 mΩ
5 0 0 mΩ
TATAL: 16mΩ
ENTER
4.20 4.19 4.19 V
4.19 0.00 0.00 V
MAIN 16.78V
H4.200V L4.195V
DC/DC CONVERTER
U=0.0V I=0.0A
ENTER
Mavic CHARGE
BEFORE CHARGING
Mavic CHARGE
TURN ON BATTERY
ENTER
TB4X CHARGE
BEFORE CHARGING
TB4X CHARGE
TURN ON BATTERY
TB4X STORAGE
BEFORE CHARGING
Mavic STORAGE
BEFORE CHARGING
Mavic CHARGE
TURN ON BATTERY
TB4X CHARGE
TURN ON BATTERY
ENTER>3Seconds
LiPo BALANCE CHG
2.0A 7.4V(2S)
LiPo CHARGE
2.0A 7.4V(2S)
LiPo STORAGE
2.0A 7.4V(2S)
LiPo DISCHARGE
1.0A 7.4V(2S)
NiMH DISCHARGE
1.0A CUT: 1.0V
NiMH RE-PEAK
1
NiMH CYCLE
CHG>DCHG 1
NiMH CHARGE
CURRENT 2.0A
DEC
INC
· 08 B6 V2 09 ·B6 V2
When you are willing to alter the parameter value in the program,
press the START/ENTER button to make it blink then change the
value by pressing DEC and INC button. The value will be stored by
re-pressing the START/ENTER button. If there is another parameter
can be altered in the same screen, when you confirm the first
parameter value, the next parameter value will start to blink which
means it is ready to alert.
When you are willing to start the progress, press and hold the
START/ENTER button for 3 seconds. When you are willing to stop the
progress or go back to previous step/screen, press the BATT
PROG/STOP button once.
When you power on the charger, it will enter LiPo Battery balance
program directly. You could change the mode (balance mode, normal
charge mode, fast charge mode, store mode or discharge mode),
enter the desired charging/discharging mode, set the referred
parameter and start the progress.
If you have no request for LiPo Battery program, please press the
BATT PROG/STOP button to enter BATT PROGRAM screen.
BATT PROG / STOP Button:
It is used to stop the progress or go back to previous step/screen
DEC Button:
It is used to go through the menus and decrease the parameter value
INC Button:
It is used to go through the menus and increase the parameter value
ENTER / START Button:
It is used to enter parameter or store parameter on screen.
Explanation of Buttons Power and Battery Connection
1. Connecting to power source
12V DC Battery / Power Adapter Output DC 11-18V
STOP STATUS START
XT60
STOP STATUS START
· 10 B6 V2 11 ·B6 V2
11-18V
Adapter
4S LiPo Battery Pack
or 12V Pb Battery
NiMH
NiCd
Pb
Batt
Type
Operation
Program
Description
RE-PEAK
In re-peak charge mode, the charger can peak charge
the battery once, twice or three times in a row
automatically. This is good for confirming the battery is
fully charged, and for checking how well the battery
receives fast charges.
CYCLE
1 to 5 cyclic and continuous process of charge>discharge
or discharge>charge is operable for battery refreshing
and balancing to stimulate the battery's activity.
LiPo
LiHV
Lilon
LiFe
This charging mode is for charging LiPo/LiHV/LiFe/LiIon
battery in normal mode.
CHARGE
This program is for charging or discharging lithium battery
which will not be used for long time.
STORAGE
This mode is for balancing the voltage of lithium-polymer
battery cells while charging.
BAL
CHARGE
The charger will charge NiMH and NiCd batteries using
the charge current set by the user.
CHARGE
COLD CHG
DISCHARGE
Charging Program
Depends on different battery type, the operation programs are different.
DISCHARGE
This mode is for discharging LiPo/LiHV/LiFe/LiIon battery.
DISCHARGE
This mode is for discharging NiMH/NiCd battery.
This mode is for charging Pb battery in cold days when the
temperature is 5 to -20.
This mode is for discharging Pb battery.
NORMAL CHG
This mode is for charging Pb battery.
AGM CHG
This mode is for charging AGM battery.
1) LiPo Battery Connection
2) NiMH/NiCd or Pb Battery Connection
STOP STATUS START
TO AVOID SHORT CIRCUITS, ALWAYS CONNECT
THE CHARGE LEADS TO THE CHARGER FIRST,
AND THEN TO THE BATTERY. REVERSE THE
SEQUENCE WHEN DISCONNECTING THE PACK.
WARNING!
2. Connecting the battery
The balance wire of the battery must be connected to the charger.
Always remember to keep right polarity in the connection. Please
refer to the wiring diagram above,which shows a correct way for
your LiPo battery connection in the balance charge mode.
In the other modes, there is no request to connect the balance wire
to the balance socket in the charger.
But we suggest to charge your battery in balance mode for better
performance.
STOP STATUS START
Power and Battery Connection
This charging mode is for charging Mavic/TB4X battery
in normal mode.
CHARGE
This program is for charging or discharging Mavic/TB4X
battery which will not be used for long time.
STORAGE
Mavic
TB4X
Charge Operation
Lithium Battery Pack
NiMH Battery Pack
· 12 B6 V2 13 ·B6 V2
50%
10.20V
00301mAhC 2.0A
R shows the number of cells detected by the
charger and S is the number of cells set by
you on the previous screen. If the two
numbers are identical, press START/ENTER
to start the charging process.
Charging Status Monitor
During charge process, real-time status will be
shown as seen on the left. Print INC or DEC,
more status will show on the screen.
Program Stop
During the charging
process, press STOP
to stop the charging
process.
Program Complete
The charger is detecting the battery cell.
R shows the number of cells detected by the
charger and S is the number of cells set by
you on the previous screen. If the two numbers
are not identical, press STOP to go back to
the previous screen to recheck the number of
cells of the battery pack that you set before
going ahead.
Once the battery is fully charged, the screen
will read “FULL” and the charger will emit a
ringing sound. The charger also displays
battery voltage, charged capacity and elapsed
time.
R:3SER S:3SER
CONFIRM(ENTER)
START/ENTER
BATTERY CHECK
...............
R:3SER S:3SER
CANCEL(STOP)
Please scan and watch the tutorial video about
how to charge LiPo battery in balance mode.
Video
Tutorial
A memory profile is available for setting and storing pertinent
information for up to 10 different program sets. Once a battery
program is stored into memory, it will be retained until changed
again manually. Recalling a program memory number makes the
charger instantly ready to go!
If you do not wish to use the battery program memories, this
charger can be manually set before each use.
(1)
(2)
The following flowchart shows how the program is set manually:
BATT/PROGRAM Select
Mode Select
Program Start
Press INC and DEC to go through all the
programs and press START/ENTER to enter
LiPo BATT Program.
Battery Setting
Press INC and DEC to go through all the
modes and press START/ENTER to enter
LiPo Balance Charge Mode.
Press START/ENTER, the present value will
start to blink. Press INC and DEC to change
the value and press START/ENTER to
confirm your setting.
At the same time, the battery pack’s cell
count will start to blink, press INC and DEC
to change the value and press START/
ENTER to confirm your setting.
Press and hold START/ENTER for 3
seconds to start the program.
BATT/PROGRAM
LiPo BATT
LiPo BALANCE CHG
2.0A 11.1V (3S)
LiPo BALANCE CHG
2.0A 11.1V (3S)
LiPo BALANCE CHG
2.0A 11.1V (3S)
LiPo BALANCE CHG
2.0A 11.1V (3S)
START/ENTER
START/ENTER
START/ENTER
START/ENTER
START/ENTER
> 3 Seconds
Lithium Battery Program (LiPo/LiFe/Lilon/LiHV) Lithium Battery Program (LiPo/LiFe/Lilon/LiHV)
FULL
12.61V
00568mAh0.0A
FULL
12.61V
00:05:250.0A
· 14 B6 V2 15 ·B6 V2
Press the ENTER button and the amp rate
value will begin blinking. Use the DEC or INC
button to adjust the value to the desired rate.
Follow the instructions provided on your battery
when setting the charge current.
Press and hold the ENTER button for 3
seconds to start charging.
Once charging has commenced, the charger
will display the following real-time information:
battery type, charging current, battery voltage,
working mode, elapsed time and charged
capacity. Once the battery is fully charged, the
screen will read "FULL" and the charger will
emit a ringing sound. You can press the STOP
button at any time during the charging process
to stop charging.
NiMH/NiCd:
This program is only suitable for charging/discharging NiMH/NiCd
batteries. The B6 V2 offers the following NiMH/NiCd charge modes:
Charge, Discharge, Re-Peak and Cycle.
Selecting the Battery Type:
After powering on the B6 V2, press the INC or DEC button repeatedly
until you reach the appropriate program for the battery type you wish
to charge. For this example we have chosen the “NiMH BATT“ or
“NiCd BATT” program. Now press the ENTER button to enter the
desired program.
NiMH/NiCd Charge Mode:
BEFORE YOU BEGIN CHARGING YOUR BATTERY, MAKE SURE
YOU HAVE READ AND UNDERSTOOD ALL OF THE WARNINGS
AND SAFETY INFORMATION CONTAINED ON PAGES 05-07.
After selecting the correct battery type, if the screen does not read
“CHARGE”, use the DEC or INC buttons to change it to the
“CHARGE” mode.
BEFORE YOU BEGIN CHARGING YOUR BATTERY,
MAKE SURE YOU ARE CHARGING NIMH/NICD
BATTERIES. CHARGING LIPO BATTERY UNDER NIMH/
NICD BATTERY PROGRAM WILL CAUSE FIRE.
WARNING!
NiMH CHARGE
CURRENT 2.0A
NiMH 2.0A 6.22V
CHG 00:02:22
START/ENTER
VARIOUS INFORMATION DURING THE PROCESS
Press INC or DEC during the charging or discharging process to
view further pertinent information on the LCD screen.
Final voltage when the program ends.
Input voltage.
Safety timer ON and duration of time in
minutes.
Capacity cut-off ON and value of the set
capacity limit.
Voltage of each cell in the battery pack
when the battery is connected with
balance lead.
Internal temperature.
Temperature probe needs to be connected
to show external temperature.
Real-time status: battery type, battery
cell count, charge current, battery pack
total voltage,working mode, elapsed
time and charged capacity.
Cut-off temperature.
3.87 3.89 3.86 V
INC
Ext. Temp ----
Int. Temp 37°C
DEC
Temp Cut-Off
    50C/122F
DEC
DEC
DEC
DEC
DEC
End Voltage
12.6V(3S)
IN Power Voltage
12.56V
Safety Timer
ON 120min
Capacity Cut-Off
ON 5000mAh
Lithium Battery Program (LiPo/LiFe/Lilon/LiHV)
NiMH/NiCd Battery Program
50%
10.20V
00301mAhC 2.0A
50%
10.20V
00301mAhC 2.0A
NiMH 2.0A 6.22V
CHG 00106mAh
· 16 B6 V2 17 ·B6 V2
NiMH DISCHARGE
1.3A CUT: 5.10V
NiMH/NiCd Battery ProgramNiMH/NiCd Battery Program
NiMH/NiCd Discharge Mode:
After selecting the correct battery type, use
the INC or DEC button to select the
“DISCHARGE” mode. Press the START
button and the amp rate value will begin
flashing. Use the INC or DEC buttons to
adjust the value to the desired discharge rate.
Press the START button again and the
voltage cut-off will begin to flash. Use the INC
or DEC button to adjust the value to the
desired rate.
Follow the instructions provided on your
battery when setting the voltage cut-off. The
T200 will stop discharging when the battery
has reached the preset voltage cut-off.
Press and hold the START button for 3
se con ds t o s tar t di sch ar gin g. O nc e
discharging has commenced, the charger will
display the following real-time information:
battery type, discharging current, battery
voltage, working mode, elapsed time and
discharged capacity.
When discharging is complete, the screen will
read “DONE” and the charger will emit a
ringing sound.
The charger will display the elapsed time, end
voltage and the discharged capacity in mAh.
You can press the STOP button at any time
during the discharging process to stop the
discharge process.
NiMH 0.6A 5.43V
DCH 00:02:22
NiMH DONE 5.10V
DISCHG 00:03:17
NiMH/NiCd Re-Peak Mode:
Applicable to NiMH and NiCD batteries only, in re-peak mode the
charger can peak- charge the battery once, twice, or three times in a
row automatically. This process is good for confirming that the battery
is fully charged and for verifying how well the battery can accept a fast
charge. A five-minute cool-down delay occurs after each re-peak
charge.
IN RE-PEAK MODE, THE B6 V2 USES THE CHARGE AMPERAGE
AND VOLTAGE SETTINGS ENTERED IN CHARGE MODE.
After selecting the correct battery type, use
the INC or DEC button to select the “RE-
PEAK” mode. Press the START button and
the Re-peak cycle number 1 begins to flash
on the screen. Use the INC or DEC button to
scroll through the cycle count and set a
number between 1 and 3.
Press and hold the START button for 3
seconds to start the re-peak process.
Once the Re-Peak process has begun, the
charger will display the following real-time
information: battery type, charging current,
battery voltage, elapsed time and charged
capacity.
Once the Re-Peak process has completed,
the screen will read “DONE” and the charger
will emit a ringing sound. The charger will
display the charge/discharge capacity for
each cycle. Using the + and - buttons, you
can scroll through the history data of each
cycle.
NiMH RE-PEAK
2
NiMH 2.0A 6.28V
RPC 00:04:04
START/ENTER
NiMH 0.6A 5.43V
DCH 00106mAh
NiMH 2.0A 6.28V
RPC 00686mAh
· 18 B6 V2 19 ·B6 V2
NiMH/NiCd Battery ProgramNiMH/NiCd Battery Program
NiMH/NiCd Cycle Mode:
The B6 V2 makes cycling of NiMH/NiCd batteries easy. The process of
discharging and recharging (cycling) can be performed automatically
with one simple step and will improve the performance of NiMH/NiCd
batteries. We strongly recommend cycling any battery that has been
discharged and stored for a period of time. This will increase the
remaining usable battery life and also improve the battery
performance.
After selecting the correct battery type, use
the INC or DEC button to select the “CYCLE”
mode. The Cycle Mode gives you two cycling
options: “DCHG>CHG” or “CHG>DCHG“. The
“DCHG>CHG” option will first discharge the
battery and then recharge the battery.
The “CHG>DCHG” option will first charge the
battery and then discharge the battery. If this
screen does not show your desired cycling
option, press the START button once and this
setting will begin flashing. Use the INC or
DEC button to change this setting.
Pressing the START button again will cause
the cycle count to begin flashing. Use the INC
or DEC button to change this to the number of
cycles you want the B6 V2 to run. The T200
can cycle the battery a maximum of 5 times
consecutively.
Press and hold the START button for 3
seconds to start the Cycle Mode.
Once cycling has commenced, the charger will
display the following real-time information:
battery type, charging/ discharging current,
battery voltage, working mode,elapsed time
and charged/discharged capacity. You will also
Once the cycling process is complete, the screen will read “DONE”
and the charger will emit a ringing sound. The B6 V2 will display the
charged/discharged capacity for each cycle. Using the + and -
buttons, you can scroll through this data for each cycle.
NiMH CYCLE
CHG > DCHG 1
NiMH CYCLE
CHG > DCHG 5
NiMH 2.0A 6.39V
C > D 00:04:04
START/ENTER
see “D>C“ or “C>D“. This will indicate which
cycling order you have chosen.
Either “D“ or “C“ will be flashing. This flashing
indicates which part of the cycle is currently
being executed.
NiMH 2.0A 6.39V
C > D 00034mAh
Additional NiMH/NiCd Process Information:
During the NiMH/NiCd battery charging/discharging process the B6
V2 can display a variety of information. Using the INC or DEC
buttons, you can also view the following information:
NiMH Sensitivity
D.Peak 4mV/CELL
Ext. Temp ----
Int. Temp 37 C
Safety Timer
ON 200min
In Power Voltage
12.56V
Temp Cut-off
50 C/122 F
Capacity Cut-Off
ON 5000mAh
Delta peak voltage sensitivity setting
External*/ internal temperature
Safety timer setting
Input Voltage
Temperature cut-off
Capacity limit setting
· 20 B6 V2 21 ·B6 V2
Pb AGM CHG
1.5A 12.0V(6P)
Press the START button again and the
nominal battery pack voltage will begin
flashing. Use the INC or DEC button to set the
voltage and the number of cells.
Press and hold the START button for 3
seconds to start charging.
Once charging has commenced, the charger
will display the following real-time information:
battery type, charging current, battery voltage,
working mode, elapsed time and charged
capacity.
When charging is complete, the screen will
read “FULL” and the charger will emit a ringing
sound.
Pb Lead-Acid Battery Program
This program is only suitable for charging
Pb(lead-acid) batteries with nominal voltage
ranging from 2 to 20V which are significantly
different from NiMH/NiCd batteries. Pb
batteries are suggested to charge with a low
current of 0.1C and cannot be used for fast
charging. Please follow the instructions
provided by the battery manufacturer.
The B6 offers the following Pb charge modes:
Charge, AGM, COLD and Discharge.
Pb (Lead-Acid):
BATT/PROGRAM
Pb BATT
Pb Charge Mode:
After selecting the correct battery type, use the INC or DEC button to
change it to the “CHARGE“ mode.
Press the START button and the amp rate value will begin flashing.
Use the INC or DEC buttons to adjust the value to the desired charge
rate. The amp rate should be set to 1/10th of capacity. For example, if
you are charging a 20Ah battery the charge rate should be set to 2A.
Follow the instructions provided on your battery when setting the amp
rate.
Pb Lead-acid Battery Program Pb Lead-acid Battery Program
Once charging has commenced, the charger
will display the following real-time information:
battery type, charging current, battery voltage,
working mode,elapsed time and charged
capacity.
When charging is complete, the screen will
read “FULL” and the charger will emit a ringing
sound.
P-6 1.5A 13.56V
CHG 00:02:22
Press the START button again and the
nominal battery pack voltage will begin
flashing. Use the INC or DEC button to set the
voltage and the number of cells.
Press and hold the START button for 3
seconds to start charging.
Pb Normal Charge
2.0A 12.0V(6P)
Pb AGM Mode:
After selecting the correct battery type, use the INC or DEC button to
change it to the “AGM CHARGE“ mode.
Press the START button and the amp rate value will begin flashing.
Use the INC or DEC buttons to adjust the value to the desired charge
rate. The amp rate should be set to 1/10th of capacity. For example, if
you are charging a 20Ah battery the charge rate should be set to 2A.
Follow the instructions provided on your battery when setting the amp
rate.
P-6 1.5A 13.56V
CHG 00106mAh
P-6 FULL 13.62V
CHG 00106mAh
P-6 1.5A 13.56V
AGM CHG 00:02:22
P-6 1.5A 13.56V
AGM CHG 00106mAh
P-6 FULL 13.62V
AGM CHG 00106mAh
· 22 B6 V2 23 ·B6 V2
Once discharging has commenced, the
charger will display the following real-time
information: battery type, cell count,discharging
current, battery voltage, elapsed time and
discharged capacity.
When discharging is complete, the screen will
read “DONE” and the charger will emit a
ringing sound.
Additional Pb Process Information:
During the Pb battery charging/discharging process the B6 V2 can
display a variety of information. Using the INC or DEC buttons you can
also view the following information:
Capacity Cut-Off
ON 5000mAh
Temp Cut-off
50 C
In Power Voltage
12.56V
Safety Timer
ON 200min
Ext. Temp ----
Int. Temp 37 C
Capacity cut-
off setting
Temperature
cut-off
Input voltage
Safety timer
setting
External*/
internal
temperature
Pb Discharge Mode:
After selecting the correct battery type, use the INC or DEC buttons
to change it to the “DISCHARGE“ mode.
Press the START button and the amp rate value will begin flashing.
Use the INC or DEC buttons to adjust the value to the desired
discharge rate. Follow the instructions provided with your battery
when setting the amp rate.
Press the START button again and the
nominal battery pack voltage will begin
flashing. Use the INC or DEC buttons to set
the voltage and the number of cells.
Press and hold the START button and
discharging will begin.
Pb Discharge
1.5A 12.0V(6P)
Pb Cold Mode:
Pb COLD CHG
1.5A 12.0V(6P)
Pb Lead-acid Battery Program Pb Lead-acid Battery Program
Press the START button again and the
nominal battery pack voltage will begin
flashing. Use the INC or DEC button to set the
voltage and the number of cells.
Press and hold the START button for 3
seconds to start charging.
Once charging has commenced, the charger
will display the following real-time information:
battery type, charging current, battery voltage,
working mode, elapsed time and charged
capacity.
When charging is complete, the screen will
read “FULL” and the charger will emit a ringing
sound.
P-6 1.5A 13.56V
COLD CHG 00:02:22
P-6 1.5A 13.56V
COLD CHG 00106mAh
P-6 FULL 13.62V
COLD CHG 00106mAh
P-6 1.5A 13.56V
DCH 00:02:22
P-6 1.5A 13.56V
DCH 00106mAh
P-6 DONE 13.62V
DCHG 00106mAh
· 24 B6 V2 25 ·B6 V2
DJI Battery Program DJI Battery Program
Press the ENTER button and the amp rate
value will begin blinking. Use the INC or DEC
button to adjust the value to the desired rate.
Follow the instructions provided on your
battery when setting the charge current.
Press and hold the ENTER button for 3 seconds
to start charging.
Once charging has commenced, the charger
will display the following real-time information:
charging current, battery voltage, working
mode, elapsed time and charged capacity.
Once the battery is fully charged, the screen
will read "FULL" and the charger will emit a
ringing sound. You can press the STOP
button at any time during the charging
process to stop charging.
This program is only suitable for charging/ discharging DJI Mavic
and TB4X battery, B6 offers two operation modes: charge and
storage.
Selecting the Battery Type:
After powering on the B6 V2, press DEC or INC, DJI BATT program
involved in the "TOOL KITS" program, press the INC or DEC button
repeatedly until you reach the appropriate program for the battery
type you wish to charge. For this example we have chosen the "DJI
DRONE BATT Mavic" or "DJI DRONE BATT TB4X" program. Now
press the ENTER button to enter the desired program.
Connect the battery to the charger as show on the diagram.
Turn on the battery before you put it in charging mode.
CONNECTION DIAGRAMCONNECTION DIAGRAMCONNECTION DIAGRAM
Note: Mavic charging cable is not included
in the package
Press the Power Button once
Then Press Again and Hold
for 2 Seconds to Turn On
BATT/PROGRAM
TOOL KITS
DJI DRONE BATT
Mavic
Charge Mode:
When the battery is idle for temporary days, it is
better to charge/ discharge the battery to 65%
of total power in order to prevent swelling.
Turn on the battery before you put it in storage
mode.
After selecting the correct battery type, use
the INC or DEC button to change the charge
mode to "STORAGE" mode setting.
Press the ENTER button and the amp rate
value will begin blinking. Use the INC or DEC
button to adjust the value to the desired rate.
Follow the instructions provided on your battery
when setting the charge current.
Press and hold the ENTER button for 3 seconds
to start charging.
Once charging has commenced, the charger
will display the following real-time information:
charging current, battery voltage, working
mode, elapsed time and charged capacity.
Once the battery is fully charged, the screen
will read "DONE" and the charger will emit a
ringing sound. You can press the STOP button
at any time during the charging process to
stop charging.
Storage Mode:
ENTER
ENTER
Mavic CHARGE
TURN ON BATTERY
BATT/PROGRAM
TOOL KITS
DJI DRONE BATT
Mavic
ENTER
ENTER
Mavic CHARGE
TURN ON BATTERY
Mavic STORAGE
TURN ON BATTERY
PRESSENTER>3"
PRESSENTER>3"
+ -
50%
10.20V
00301mAhC 2.0A
FULL
12.61V
00568mAh0.0A
FULL
12.61V
00:05:250.0A
50%
10.20V
00301mAhC 2.0A
DONE
12.61V
00568mAh0.0A
DONE
12.61V
00:05:250.0A
· 26 B6 V2 27 ·B6 V2
DC / DC Converter
B6 V2 charger is integrated with a DC/DC converter. A DC/DC
converter is an electronic circuit that converts a source of direct
current (DC) from one voltage level to another. It is a type of electric
power converter. For B6 V2, the output voltage range from 5-26V
and output current range from 1-6A. The maximum power is 60W.
This program can be found in the "TOOL
KITS", press DEC or INC button repeatedly
until you reach "DC/DC CONVERTER"
program, double press the ENTER, then
press DEC or INC to set the output voltage
and current.
Press and hold the ENTER button for 3
seconds, the charger will start to work as
a power supply, you can read the output
voltage/ current / power on the screen.
Battery Memory Set and Call Out
[ B A T T M EM O R Y 1 ]
E N T E R SE T - >
B A T T T YP E
L i P o
B A T T V OL T S
7 . 4 V ( 2 S )
C H A R GE C U R R EN T
4 . 9 A
D S C H C UR R E N T
2 . 0 A
D S C H V OL T A G E
3 . 0 V /C E L L
START/ENTER
DEC INC
DEC INC
DEC INC
DEC INC
DEC INC
The charger can store up to 10 different charge/discharge profiles for
your convenience, and the stored profiles can be recalled quickly
without having to go through the setup process.
When you are willing to alter the parameter value in the program,
press START/ENTER to make it blink then change the value with INC
or DEC. The value will be stored by pressing START/ENTER once.
Note: All following screen are taking 2S(7.4V) LiPo battery for
example.
Enter the battery memory program.
(10 different charge/discharge profiles can
be stored).
Set the battery type(LiPo/LiHV/LiFe/LiIon/
NiMH/NiCd/Pb).
Set the voltage and number of cells(1-6S).
Set the charge current(0.1-6.0A).
Set the discharge current (0.1A-2.0A).
Set the discharge voltage(3.0-3.3V/Cell).
1. Battery Memory Set
BATT/PROGRAM
TOOL KITS
DC/DC CONVERTER
U=0.0V I=0.0A
ENTER
ENTER
PRESSENTER>3"
Caution: The maximum DC Power output is 60 Watts. Please check
your device loading before you allocate the power.
· 28 B6 V2 29 ·B6 V2
DC/DC CONVERTER
U=6.0V I=3.4A
U=5.9V I=1.2A
POWER=7W
STOP STATUS START
DC Input
(11-18V)
DC Output
(5-26V / 1-6A)
E N T ER C H A R G ER
L O A D
L i P o BA L A N C E CH G
4 . 9 A 7. 4V ( 2 S)
S A V E PR O G R A M
S A V E .
[ B A T T ME M O R Y 1 ]
L i P o  7. 4 V ( 2 S )
[ B A T T ME M O R Y 1 ]
C : 4 .9 A D: 2 . 2A
START/ENTER
>3 Seconds
T V C = YO U R R I SK
4 . 2 0 V
DEC INC
S A V E P RO G R A M
E N T E R
START/ENTER
Set the terminal voltage(4.18-4.25V).
Press ENTER to save program.
Indicate the battery type and battery cell of the
saved profile.
Indicate the charge and discharge current of
the saved profile.
Press the START/ENTER for 3 seconds to call
out the memory.
2. Battery Memory Call Out
Load the memory set
Press START/ENTER for 3 seconds to start
the process.
Battery Memory Set and Call Out System Setting
S a f e t y T i m er
O N 1 2 0 M i n
R e s t T i m e
C H G > D C H G 1 0 Mi n
C a p a c i t y C ut - Of f
O N 5 0 0 0 m A H
T e m p e r a t ur e U ni t
C e l s i u s
T e m p C u t - O ff
O N 5 0 C 12 2 F
This program sets the maximum
charge capacity that will be
supplied to the battery during
charge. If the delta peak voltage is
not detected nor the safety timer
expired by any reason, this feature
will automatically stop the process
at the selected capacity value.
When you start a charge process,
the integral safety timer
automatically starts running at the
same time. This is programmed to
prevent overcharge the battery if it
proves to be faulty, or if the
termination circuit cannot detect
the battery full. The value for the
safety timer should be generous
enough to allow a full charge of
the battery.
The battery's internal chemical
reaction will cause the
temperature of the battery to rise.
If the temperature limit is reached,
the process will be terminated.
OFF/
ON
(100-50000mAh)
It will be operated with the default value of the essential user settings
when it is powered on for the first time.The screen displays the
following information in sequence and the user can change the value
of parameter on each screen.
When you are willing to alter the parameter value in the program,
press START/ENTER to make it blink then change the value with INC
or DEC. The value will be stored by pressing START/ENTER once.
ITEM SELECTION DESCRIPTION
OFF/
ON
(1-720 Min)
OFF/
ON
(20 C/68 F -
80 C/176 F)
Celsius
Fahrenheit
1-60Min
A rest time allowing the battery to
cool down between
charging/discharging cycle.
You can choose the temperature
displayed by Celsius or Fahrenheit
as you like.
· 30 B6 V2 31 ·B6 V2
ITEM
SELECTION DESCRIPTION
N i M HS e n s i ti v it y
D . P e a k D e f au l t
N i C dS e n s i ti v it y
D . P e a k D e f au l t
Default:
4mV/Cell
3-15mV/Cell
K e y B e e p O N
B u z z e r O N
OFF/ON
The beep sounds at every time
touching the buttons to confirm
your action. The beep or melody
sounded at various times during
operation to alert different mode
changes.
L o a d F a c t o ry S e t
E n t e r
V e r s i o n
H W : 1 . 0 0 S W : 1. 0 4
This program is for NiMH/NiCd
battery only. When the charger
detects the delta peak value
reaches the value you set, the
charger will say the battery is fully
charged.
Press ENTER to load factory
default setting.
It indicates the hardware and
firmware version.
D C I n p u t L o w
C u t - O f f 1 1 .0 V
10-12V
There will be error message when
DC input voltage is lower than the
reset value.
System Setting
Battery Voltage Meter
STOP STATUS START
The user can check battery's total voltage, the highest voltage, the
lowest voltage and each cell's voltage.
Please connect the battery to the charger main battery lead to
battery socket and balance wires to balance socket.
Press the START/ENTER to enter the Lithium
Battery Meter program.
The screen indicate each cell's voltage.
The screen indicate the total voltage, the
highest voltage and the lowest voltage.
B A T T/ P R O G RA M
B A T T ME TE R
4 . 2 0 4. 1 9 4 . 1 9 V
4 . 1 8 4. 1 8 4 . 1 9 V
M A I N 25 . 1 3 V
H 4 . 20 0 V L 4 . 18 2 V
START
ENTER
INC
This diagram shows
the correct way to
connect your battery
to check the voltage.
Lithium Battery Pack
4.20 4.19 4.19V
4.18 4.18 4.19V
· 32 B6 V2 33 ·B6 V2
Battery Resistance Meter
The user can check battery's total resistance, the highest resistance,
the lowest resistance and each cell's resistance.
Please connect the battery to the charger main battery lead to battery
socket and balance wires to balance socket.
Press the START/ENTER to enter the Lithium
Battery Resistance program.
The screen indicate each cell's resistance.
The screen indicate the total resistance, the
highest resistance and the lowest resistance.
Start
Enter
B A T T/ P R O G RA M
B A T T RE S I S T AN C E
0 1 2 0 05 0 05 mΩ
0 0 6 0 08 0 06 mΩ
T A T A L:4 2 mΩ
INC
STOP STATUS START
Lithium Battery Pack
This diagram shows
the correct way to
connect your battery to
check the resistance.
Warning and Error Message
In case of an error the screen will display the cause of error and emit
an audible sound.
Incorrect polarity connected.
The battery is interrupted.
The battery cell you sent is different from what
charger detected.
Input voltage less than 11V
Input voltage higher than 18V
The internal temperature of the unit goes too high.
The external temperature of the battery goes
too high.
The battery capacity is more than the maximum
capacity which the user sets.
The charging time is longer than the maximum
charging time which the user sets.
Battery voltage wrong.
One cell voltage of your battery is too high.
Wrong battery type.
C E L L N O T M A T C H
S U P P L Y V O L T
T O O L O W
I N T E R N A L T E MP .
T O O H I G H
S U P P L Y V O L T
T O O H I G H
B A T T T E M P E R AT U RE
T O O H I G H
O V E R C H A R G E
C A P A C I T Y L I MI T
O V E R T I M E L I M IT
V O L T E R R O R
C E L L V O L T E R R O R
W R O N G B A T T T Y P E
0 1 2 0 0 5 0 0 5 mΩ
0 0 6 0 0 8 0 0 6 mΩ
· 34 B6 V2 35 ·B6 V2
THESETCONTAINS
Specification
Balance Current: 300mA/cell
Reading Voltage Range: 0.1-26.1V/cell
Battery Types/Cells: LiPo/LiHV/LiFe/LiIon: 1-6cells
NiMH/NiCd: 1-15cells
 Pb: 2-20V
Battery Capacity Range: NiMH/NiCd: 100-50000mAh
LiPo/LiHV/LiFe/LiIon: 100-50000mAh
Pb: 100-50000mAh
Charge Current: NiMH/NiCd/LiPo/LiHV/LiFe/Li-ION/Pb: 0.1A-6.0A
DJI Mavic/TB4X: 4A
Safety Timer: 1-720minutes off
Charge Wattage: 60W
Discharge Current: 0.1A-2.0A
Discharge Cut-off Voltage: NiMH/NiCd: 0.1-1.1V/cell
LiPo: 3.0-3.3V/cell LiHV: 3.1-3.4V/Cell
LiFe: 2.6-2.9V/cell LiIon: 2.9—3.2V/cell
Pb: 1.8-2.0V/cell
Discharge Wattage: 5W
Balance Cells: 2-6 cells
Memory: 10 different charge/discharge profiles
Charge Method: CC/CV for lithium types and lead (Pb) batteries
Delta-peak Sensitivity for NiMH/NiCd.
DC Input Voltage:11-18V
Display Type: 2x16 LCD Display Backlight: Blue
Case Material: Aluminium Controls: Four Buttons
Case Size: 115x84x31mm Weight: 238g
External Port: 1-6S Balance Socket-XH, Temperature Probe Socket,
Battery Socket, DC Input.
Delta Peak Detection for NiMH/NiCd: 3-15mV/cell / Default: 4mV/cell
Battery Cutoff Temperature: 20ºC/68ºF-80ºC/176ºF(adjustable)
Charge Voltage: NiMH/NiCd: Delta peak detection
 LiPo: 4.18-4.25V/cell
LiHV:4.25-4.35V/cell
LiFe: 3.58-3.7V/cell
LiIon: 4.08-4.2V/cell
Pb Normal:2.4V/cell
Pb AGM:2.45V/cell
Pb Cold:2.45V/cell
Ec3 Charging Cable
SK-600023-13
Dean Charging Cable
SK-600023-15
Tamiya Charging Cable
SK-600023-12
4mm/5mm Bullet
Charging Cable for 2S Battery
SK-600023-14
5mm
4mm
Temperature Sensor
SK-600040-01
RECOMMENDED ACCESSORIES
The Set Contains
· 36 B6 V2 37 ·B6 V2
1. SKYRC B6 V2 Charger
2. DC Input Cable
3. Dean Charging Cable
4. Bare charging cable
5. Instruction Manual
ersion 1.00]
1
2
5
3
4
Instruction Manual
[Version 1.00]
This symbol means that you must dispose of electrical from the
General household waste when it reaches the end of its useful
life. Take your charger to your local waste collection point or
recycling centre. This applies to all countries of the European Union,
and to other European countries with a separate waste collection
system.
SkyRC B6 V2 satisfy all relevant and mandatory EC directives and FCC
Part 15 Subpart B.
FCC Part 15, Subpart B
Radiated Emission
Conformity Declaration Regulatory Information
FCC Note:
This device complies with Part 15 of the FCC rules. Operation is
subject to the following two conditions:
(1) this device may not cause harmful interference, and (2) this device
must accept any interference received, including interference that
may cause undesired operation.
The manufacturer is not responsible for any radio or TV interference
caused by unauthorized modifications or change to this equipment.
Such modifications or change could void the user's authority to
operate the equipment.
This equipment has been tested and found to comply with the limits
for a Class B digital device, pursuant to part 15 of the FCC Rules.
These limits are designed to provide reasonable protection against
harmful interference in a residential installation. This equipment
generates, uses and can radiate radio frequency energy and, if not
installed and used in accordance with the instructions, may cause
harmful interference to radio communications. However, there is no
guarantee that interference will not occur in a particular installation. If
this equipment does cause harmful interference to radio or television
reception, which can be determined by turning the equipment off and
on, the user is encouraged to try to correct the interference by one or
more of the following measures:
– Reorient or relocate the receiving antenna.
– Increase the separation between the equipment and receiver.
Connect the equipment into an outlet on a circuit different from that
to which the receiver is connected.
– Consult the dealer or an experienced radio/TV technician for help.
To maintain compliance with FCC's RF exposure guidelines, this
equipment should be installed and operated with a minimum distance
of 20cm between the radiator and your body.
· 38 B6 V2 39 ·B6 V2
EN 55014-1:2006
+ A1:2009+A2:2011
Electromagnetic compatibility-Requirements
for household appliances, electric tools and
Similar apparatus – Part 1: Emission
EN 55014-2:1997+
A1:2001+ A2:2008
Electromagnetic compatibility-Requirements
for household appliances, electric tools and
Similar apparatus – Part 2: Immunity-Product
family standard
Commonly Used Terms
Commonly used terms
Final charge voltage: the voltage at which the battery's charge limit
(capacity limit) is reached. The charge process switches from a high
current to a low maintenance rate (trickle charge) at this point. From
this point on further high current charging would cause overheating
and eventual terminal damage to the pack.
Final discharge voltage: the voltage at which the battery's discharge
limit is reached. The chemical composition of the batteries determines
the level of this voltage. Below this voltage the battery enters the deep
discharge zone. Individual cells within the pack may become reverse
polarized in this condition, and this can cause permanent damage.
A, mA: unit of measurement relating to charge or discharge
current.1000 mA = 1 A (A=Ampere,mA=Milliampere)
Ah, mAh: unit of measurement for the capacity of a battery (Amperes
x time unit; h = hour). If a pack is charged for one hour at a current of 2
A, it has been fed 2 Ah of energy. It receives the same quantity of
charge (2 Ah) if it is charged for 4 hours at 0.5 A, or 15 minutes (=1/4
h) at 8 A.
'C'-rating: Capacity is also referred to as the 'C' rating. Some battery
suppliers recommend charge and discharge currents based on the
battery 'C' rating. A battery's '1C' current is the same number as the
battery's rated capacity number, but noted in mA or amps. A 600mAh
battery has a 1C current value of 600mA, and a 3C current value of (3
x 600mA) 1800mA or 1.8A. The 1C current value for a 3200mAh
battery would be 3200mA (3.2A).
Nominal voltage(V): The nominal voltage of the battery pack can be
determined as follows;
-.NiCd or NiMH: multiply the total number of cells in the pack by 1.2. A
8-cell pack will have a nominal voltage of 9.6 volts (8x1.2).
-.LiPo: multiply the total number of cells in the pack by 3.7. A 3-cell
LiPo wired in series will have a nominal voltage of 11.1 volts (3x3.7).
-.LiIo: multiply the total number of cells in the pack by 3.6. A 2-cell LiIo
wired in series will have a nominal voltage of 7.2 volts (2x3.6).
-.LiFe: multiply the total number of cells in the pack by 3.3. A 4-cell LiIo
wired in series will have a nominal voltage of 13.2 volts (4x3.3).
If the nominal voltage of the battery is not printed on the battery's label,
consult your battery manufacturer or supplier. Do not guess the rated
voltage of battery.
Warranty and Service
This charger is designed and approved exclusively for use with the types of
battery stated in this Instruction Manual. SkyRC accepts no liability of any
kind if the charger is used for any purpose other than that stated.
We are unable to ensure that you follow the instructions supplied with the
charger, and we have no control over the methods you employ for using,
operating and maintaining the device. For this reason we are obliged to
deny all liability for loss, damage or costs which are incurred due to the
incompetent or incorrect use and operation of our products, or which are
connected with such operation in any way.Unless otherwise prescribed by
law, our obligation to pay compensation, regardless of the legal argument
employed, is limited to the invoice value of those SkyRC products which
were immediately and directly involved in the event in which the damage
occurred.
Liability exclusion
Warranty and service
We guarantee this product to be free of manufacturing and assembly defects
for a period of one year from the time of purchase. The warranty only applies
to material or operational defects, which are present at the time of purchase.
During that period, we will repair or replace free of service charge for products
deemed defective due to those causes.
This warranty is not valid for any damage or subsequent damage arising as a
result of misuse, modification or as a result of failure to observe the procedures
outlined in this manual.
The warranty service is valid in China only.
If you need warranty service overseas, please contact your dealer in the
first instance, who is responsible for processing guarantee claims
overseas. Due to high shipping cost, complicated custom clearance
procedures to send back to China. Please understand SkyRC can't
provide warranty service to overseas end user directly.
If you have any questions which are not mentioned in the manual,
please feel free to send email to [email protected]
Note:
1.
2.
3.
· 40 B6 V2 41 ·B6 V2